Mobile ✓ lists are based on Washington State building codes effective July 1st, 2013. (*) defines codes which have been amended by the Washington State Code Council.
Landings – R311.3, R311.7.6
Attachment – R311.5.1
Rise/Run – R311.7.5.1, R311.7.5.2
Width – R311.7.1
Headroom – R311.7.2
Nosing – R311.7.5.3
Illumination – R303.7, R311.7.9
Fire blocking – R302.11 (#3)
Handrails – R311.7.8
Door to dwelling – R302.5.1
Duct penetration – R302.5.2
Fire separation – Table R302.6
Floor surface – R309.1
Appliance height – M1307.3
Impact protection – M1307.3.1
Energy Certificate – WSEC 401.3
Carports – R309.2
Access – R408.4
Access insulation – WSEC R402.2.4
Floor Insulation – WSEC R402.2.7
Debris – R408.5
Ventilation* – R408.1, R408.2
Decay resistance – R317.1
Duct earth clearance – M1601.4.7
Ground contact –R317.1.2
Appliance access – M1305.1.4
Access – R807.1
Access insulation – WSEC R402.2.4
Appliance access – M1305.1.3
Appliance light – M1305.1.3.1
Depth markers – WSEC R303.1.1.1
Ventilation- R806.1
Eave baffle – WSEC R402.2.3
Air / insulation space – R806.3
Stairs / ladders* – R311.4
Smoke alarm location* – R314.3
C / O alarms* – R315.1
Safety glass – R308.1
Window fall protection – R312.2
Guards – R312.1
Egress door – R311.2
Exterior wall rating* -Table R302.1
Egress Window – R310.1
Landing – R311.3, R311.7.6
Stairs – R311.7
Emergency egress – R310.1
Window well – R310.2
Egress under decks – R310.5
Smoke alarms* – R314.3
C / O alarms* – R315.1
Ceiling height – R305.1.1
Wall insulation – WSEC R402.2.8
Slab insulation – WSEC R402.2.9
Insulation certificate – WSEC R303.1.1
Depth markers – WSEC R303.1.1.1
Observable R value – WSEC R303.1.2
Energy Certificate – WSEC R401.3
Eave baffle – WSEC R402.2.3
Hatches / Doors – WSEC R402.2.4
Air leakage test – WSEC R402.4.1.2
Air barrier – WSEC Table R402.4.1.1
Thermostat required – WSEC R403.1
Fan size – WSEC Table 403.5.1
Fixture clearance – Figure R307.1
Anti scald – (Shower) UPC 408.3, (Tub) UPC 409.4
Safety glass – R308.4.5
Floor & wall surface – R307.2
Dryer duct general – M1502.4.2
Duct length – M1502.4.4.1
Transition duct – M1502.4.3
Length label – M1502.4.5
Seismic straps – M1307.2
Elevation – M1307.3
Expansion tank – UPC 608.3
Pressure/Temp valve – UPC 504.6
Relief valve drain – UPC 608.5
Impact protection – M1307.3.1
Prohibited location – M2005.2
Drain pan – UPC 507.4
Relief drain – UPC 608.5
Shutoff value required – G2420.1, G2420.5
Sediment trap – G2419.4
Prohibited locations – G2415.3
Shield plates – G2415.7
Corrosion protection – G2415.11
Support – G2418.2, G2424.1
Test pressure – G2417.4.1
Test duration – G2417.4.2
Appliance connections – G2422.1
6,009 total views, 4 views today